Kanomax 2211 Indoor Air Quality Monitor
Condition: Brand New
Kanomax 2211 Multi-Parameter Indoor Air Quality Monitor
Features:
- Simultaneously measures and data log multiple parameters such as CO, CO2, Temperature, and Relative Humidity, to monitor indoor air quality conditions.
- Calculates Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air.
- Built-in memory allows user to store multiple point measurements. Equipped with RS232C terminal.
Benefits:
- Easy user calibration with built-in calibration function.
- Capable to continuously monitor parameters via PC.
- Relative Humidity and Temperature measurements help determine thermal comfort levels.
- Large LCD shows multiple parameters at a glance.
- No need of psychometric chart - Calculates dew point, wet bulb temperature, absolute humidity and humidity ratio!
Specifications:
- CO
Range: 0~500PPM Accuracy: +/-3% of reading or +/-3PPM whichever is greater Resolution: 0.1PPM: 0-99PPM 1PPM: 100-500 PPM
- CO2
Range: 0~5000PPM Accuracy: +/-3% of reading or+/-50PPM whichever is greater Resolution: 1PPM
- Temperature
Range: - 4 -140F (-20~60C) Accuracy: +/- 1F (+/-0.5C) Resolution: 0.1F (0.1C )
- Relative Humidity
Range: 2~98%RH (0.1%RH step) Accuracy: 2~80%RH:±2%RH, 80~98%RH:±3%RH Resolution: 0.1%RH
- Function
Normal Mode: Normal measuring (do not store and calculate the data.) Relative humidity, CO, CO2, Dew point, Wet bulb temperature, Absolute humidity and Humidity Ratio Calculation Mode: Store the data, and calculate the maximum, minimum and average value. % OA Mode Measure ventilation ratio (Ask for ventilation ratio by calculating from temperature and CO2 value) Data Output Mode: Perform re-calculation of stored data and output of data to PC and Printer. Calibration Mode: Perform the calibration of CO and CO2.
- Output
Digital: RS-232C (Baudrate:4800,9600,19200,38400bps) Analog: (Optional) DC0~1V (Select 1 ch among CO, CO2, temperature, and relative humidity)
- Power Supply:
AA Battery×6(Alkaline or Ni-Cd) AC adapter:AC100~240V (50/60Hz) (Optional)
- Battery Life: Approximately 10 hours (at 77F (25 C) with alkaline batteries, without RS232C)
- Operating Environment
Main Body: 41-104F (5~40C) Probe: - 4 - 140F (-20~60C)
- Storage Environment: - 4- 140F (-20~60C)
- Standard Kit: Operation Manual×1, Mn Battery ×6, Probe stand, Calibration cap, Connection tube, and hard carrying case
- Optional Accessories: Analog Output, Serial Printer, Communication Cable (For computer and printer), AC adapter.
|
|