My Account
View Cart
View Quotes
Contact Us
   
Home | About Calright | Products | Ordering & Shipping | Customer Service | Repair Service | Sell Your Equipment




Amplifiers
Analyzers
Anemometer/ Airflow
Battery Measurement
Calibrators / Standards
Clamp-On Meters
Counters, Frequency
Electrical Test
Fiber Optic / Lightwave
Force Gauges & Force Stands
Function Generators
Gloss Meters
Light Meters
Meters / Multimeters
Hipot / Ground Testers
Indoor Air Quality (IAQ)
Insulation & Earth Testers
Miscellaneous
Moisture Meters
Network Analyzers
Oscilloscopes
Particle Counter
Phase Rotation & Motor Testers
Porosity Detectors
Power Quality
Power Supplies / AC Sources / Electronic Loads
Pressure
Pulse Generators
RF / Microwave
Scales
Signal Generators
Sound Level Meters
Spectrum Analyzers
Stopwatches/ Timers
Tachometers / Stroboscopes
Telecom / Datacom
Temperature & Humidity
Thermal Imaging
Vibration Meters
Video
Water Quality


Isotech Jupiter 650 High Temperature Dry Block Calibrator, Ambient to 650ºC

Condition: Brand New


The Jupiter 650 Dry Block range offers industry-leading performance in an easy to use portable package. With its wide temperature range the Jupiter 650 will reach that important 1200°F mark making it ideal for the calibration of thermocouples as well as platinum resistance thermometers. It has been designed for fast heating and cooling for convenient field use. For flexibility surface sensor and infrared thermometer accessories can be added.

The standard insert can hold up to six thermometers. For larger blocks see the Gemini and Medusa models. All Isotech calibrators including the Jupiter 650 include a customized controller with 5 point linearization allowing for unmatched absolute accuracy and repeatability in a portable dry block.

The SITE model includes a universal sensor input allowing Platinum Resistance Thermometers, Thermocouples (K, N, R, S, L, B, PL2, T, J & E) along with Linear Process Inputs including 4-20mA current transmitters to be displayed on the built-in indicator. The SITE indicator is commonly used to display an external standard thermometer giving greater accuracy by eliminating temperature gradient and loading errors. The indicator also can be programmed with up to five calibration points to provide high accuracy digital probe matching.

Features:

  • Calibrate Whole Calibration Loop - Using a heat source rather than an electrical simulator, a test instrument and sensor can be calibrated as a system
  • Excellent Temperature Uniformity - Careful design and research allows use of a high conductivity heater block
  • Wide Operating Range - Fast response from ambient to 650ºC (1202°F) ideal for field use
  • Simple To Use and Outstanding Value

To view product configuration, specifications and current pricing please download the pdf specification sheet below. If you need assistance configuring a product or would like to place an order please call us toll free at 1.866.363.6634
Stock Number:  IT-Jupiter 650


View Specification Sheet (PDF - 0.05 MB)


Isotech Jupiter 650 High Temperature Dry Block Calibrator, Ambient to 650ºC




Home | About Calright | Products | Ordering & Shipping | Customer Service | Sell Your Equipment
Repair Service | My Account | View Cart | View Quotes | Contact Us | Site Map
Privacy Policy | Terms of Use | Terms and Conditions of Sale

Copyright© 2004 by Calright Instruments, All Rights Reserved
Web Site by Regency Web Services, Inc.

  Web Site v2.0 (Build 3.7) (09/26/2008 01:45 PM) / Ready-Flex-Go v1.5 (Build 0.80)