Hioki 8860-50 High Speed Memory Recorder / Digital Oscilloscope, 16 Channels
Condition: Brand New
Presenting two new MEMORY HiCORDERs from HIOKI that offer a whole new level of performance and functionality - use the memory function as you would on an oscilloscope for quick and easy waveform observations, and the multi-channel logger function to capture trend graphs in real time. Take advantage of the intuitive graphic user interface by setting and controlling the MEMORY HiCORDER with the click of a mouse, and upload and share files through a LAN for ultimate network compatibility.
Independent sampling measurement and 16-bit high-resolution detail help to positively identify even complex target phenomena. The plug-in slot design caters to a wide selection of interchangeable input modules, including those for other members of the HIOKI MEMORY HiCORDER series (Models 8826/8835/8841/8842 ), to meet all kinds of application needs.
With the new 8860-50 and 8861-50 MEMORY HiCORDERs, you now have the perfect means to conduct precise signal observations including voltage/current, temperature, pulse, distortion monitoring and much, much more.
Note: The MEMORY HiCORDER 8860-50 and 8861-50 cannot operate alone. You must install one or more optional input modules in the unit.
Capabilities and Features:
- 20 MS/s high-speed sampling
- Up to 16 isolated input channels (high-speed signals)
- Real-time saving to hard disk
- Dual-timebase sampling for simultaneous fast and slow monitoring
- Multi-channel logging on up to 64 channels (low-speed signals)
- Model 8860-50 with four slots
- Model 8861-50 with eight slots
Enhancements from Earlier Models 8860 and 8861:
- Enhancements from Earlier Models 8860 and 8861
- A faster CPU greatly enhances instrument operability and response.
- Three USB 2.0 ports support a USB storage device along with mouseand keyboard.
- New REC&MEM (Recorder and Memory) function.
- Capture waveforms of high-speed transients while simultaneouslyrecording at slow speed.
- New LCD with wider viewing angle for easier waveform observation.
- Uses the same input modules as previous models.
- Supports the new high-voltage input module for measuring high voltage directly
| Specifications |
|
| Number of input Units |
Max. 4 units |
| Number of channels |
Max. 16 analog channels (max. 64 channels with scanner unit) + 16 logic channels (standard configuration) |
Measurement ranges (20 div full-scale) |
5mV to 20V/div, 12 ranges, (using the 8956), resolution : 1/100 of range |
| Max. allowable input |
DC 400V (using the 8956) |
| Frequency characteristics |
DC to 10MHz (using the 8956)
|
| Power consumption |
100 to 240 V AC (50/60 Hz) (220 VA max. printer not used) 12 V DC (use the DC POWER UNIT 9684 : option, factory installation only) |
| Time axis |
5 µs to 5 min/div, 26 ranges, sampling period : 1/100 of range, external sampling, dual timebase possible |
| Data storage media |
PC Card Type II slot × 2, Hard disk drive (option) × 1 |
| Measurement functions |
MEM (high-speed recording) REC (real-time recording) REC & MEM (realtime recording + high-speed recording) FFT (frequency analysis) Real-time Save (records directly to storage media) |
| Memory capacity |
12-bits × 32M-Words/ch (1ch at 8860-50, 2ch at 8861-50) to 2M-Words/ch (16ch at 8860-50, 32ch at 8861-50) *Memory capacity can be expanded 32 times.(Optional memory board) |
| Display |
10.4 inch TFT color LCD (SVGA, 800 × 600 dots) |
| Dimensions |
330 mm (12.99 in) W × 250 mm (9.84 in) H × 184.5 mm (7.26 in) D |
| Supplied accessories |
Power cord × 1, Input cord label × 1, Application Disk (Wave Viewer Wv, Communication Commands table) × 1 |
View Specification Sheet (PDF - 1.70 MB)
|