Ametek/ Jofra MTC (Marine) Series Dry Block Temperature Calibrator
Condition: Brand New
The Jofra MTC series of portable temperature calibrators makes it very easy to maintain correct readings for all your temperature monitoring devices. The dry-block design does not use any hazardous hot liquid, has a larger temperature range and heats up and cools down much faster than a traditional liquid bath.
The MTC dry-block calibrators has been designed for much easier true temperature calibration in the field, leading to reliable results. The simple operation and the automatic functions have been carefully selected for ease of use. This has resulted in a fast, simple and efficient temperature calibrator without compromising quality. Reach 320°C (608°F) in just 4 minutes.
The MTC series features a large backlit display showing a lot of useful information at the same time: The set value and the true temperature, the status on the thermo switch test input, a count- down time before the temperature is stable and a big check mark when it is stable. To save time use the automatic switch test. The MTC series will find the open and close temperatures on a thermo switch and calculate the dead band.
The MTC series also features an auto-step function. Using this function you may stay in the control room and monitor the temperature reading while the calibrator automatically steps through a number of pre-programmed temperatures located next to the sensor.
Features:
- Interchangeable inserts
- Multi-hole insertion tubes
- MVI Mains Variance Immunity
- Automatic switch test
- Multi information display
- Safety banana bushings
- Auto stepping
- Stability indicator
- Count down timer (shows when unit is stable)
- Programmable maximum temperature
- Fast simulation/training mode
- Re-calibration from keyboard
- RS232 and JOFRACAL calibration software
Model and Temperature Range
- MTC-140 A -17 to 140°C (-1 to 284°F)
- MTC-320 A 50 to 320°C (122 to 608°F)
- MTC-650 A 50 to 650°C (122 to 1202°F)
| Selection guide MTC Series |
MTC-140 A |
MTC-320 A |
MTC-650 A |
| Temperature range @ ambient 23°C / 73°F |
-17 to 140°C (-1 to 284°F) |
33 to 320°C (91 to 608°F) |
33 to 650°C (91 to 1202°F) |
| Heating time |
15 min. |
4 min. |
10 min. |
| Immersion depth |
110 mm |
115 mm |
115 mm |
| Accuracy |
±0.5°C |
±0.5°C |
±0.9°C |
| Stability |
±0.05°C |
±0.1°C |
±0.1°C |
| Resolution |
0.1°C |
0.1°C |
0.1°C |
| Read-out |
°C and °F |
°C and °F |
°C and °F |
The JOFRACAL software program saves the operator time on lengthy documentation work. The software is delivered as standard with all JOFRA dry-block calibrators, the JOFRA DTI-1000 reference thermometer, the JOFRA DTI050 reference indicator, the JOFRA ASM multi scanner and the JOFRA ASC300 multi-signal calibrator. Besides this, JOFRACAL also supports the use of liquid baths, ice points, or other manual dry-block heat sources. JOFRACAL calibration software can be used for post-processing and printing of certificates. The calibration data collected may be stored in the personal computer for later recall or analysis.